Optimizer Options
Last updated
Last updated
The Optimizer Options is a set of parameters used to fine-tune the study optimization strategy during the optimize step.
Optimizer options have the following structure:
Field | Type | Value restrictions | Description |
---|---|---|---|
The safetyFactor
field specifies how much the optimizer should stay on the safe side in evaluating a candidate configuration with respect to the goal constraints. A higher safety factor corresponds to a safer configuration, that is a configuration that is less likely to violate goal constraints.
Acceptable values are all the real values ranging between 0 and 1, with (safetyFactor
- 0.5) representing the allowed margin for staying within the defined constraint:
0 means "no safety", as with this value the optimizer totally ignores goal constraint violations;
0.5 means "safe, but no margin", as with this value the optimizer only tries configurations that do not violate the goal constraints, by remaining as close as possible to them;
1 means "super safe", as with this value the optimize only tries configurations that are very far from goal constraints.
For live optimization studies, 0.6 is the default value, while for offline optimization studies, the default value is 0.5.
For offline optimization studies, the optimizerOptions
field can be used to specify whether beta-warping optimization (a more sophisticated optimization that requires a longer time) should be used and for how many experiments (as a percentage):
where experimentsWithBeta
can be:
A percentage between 0 and 100%
A number less than or equal to numberOfExperiments
For live optimization studies, the optimizerOptions
field can be used to specify several important parameters governing the live optimization:
Notice that while available as independent options, the optimizer options onlineMode
(described here below), workloadOptimizedForStrategy
(here below) and the safetyFactor
(see above) work in conjunction according to the following schema:
All these optimizer options can be changed at any time, that is while the optimization study is running, to become immediately effective. The Optimizer options commands page in the reference guide provides these specific update commands.
The onlineMode
field specifies how the Akamas optimizer should operate:
RECOMMEND
: configurations are recommended to the user by Akamas and are only applied after having been approved (and possibly modified) by the user;
FULLY AUTONOMOUS MODE
: configurations are immediately applied by Akamas.
The safetyMode
field describes how the Akamas optimizer should evaluate the goal constraints on a candidate configuration for that configuration to be considered valid:
GLOBAL
: the constraints must be satisfied by the configuration under all observed workloads in the configuration history - this is the value taken in case onlineMode
is set to RECOMMEND
;
LOCAL
: the constraints are evaluated only under the workload selected according to the workload strategy - this should be used with onlineMode
set to FULLY_AUTONOMOUS
.
Notice that when setting the safetyMode
to LOCAL
, the recommended configuration is only expected to be good for the specific workload selected under the defined workload strategy, but it might violate constraints under another workload.
The workloadOptimizedForStrategy
field specifies the workload strategy that drives how Akamas leverages the workload information when looking for the next configuration:
MAXIMIN
: the optimizer looks for a configuration that maximizes the minimum improvements for all the already observed workloads;
LAST
: for each workload, the last observed workload is considered - this works well to find a configuration that is good for the last workloads - it is often used in conjunction with a LOCAL
safety mode (see here above);
MOST_VIOLATED
: for each workload, the workload of the configuration with more violations is considered.
The explorationFactor
field specifies how much the optimizer explores the (unknown) optimization space when looking for new configurations. For any parameter, this factor measures the difference between already tried values and the value of a new possible configuration. A higher exploration factor corresponds to a broader exploration of never-tried-before parameter values.
Acceptable values are all the real values ranging between 0 and 1, plus the special string FULL_EXPLORATION
:
0 means "no exploration", as with this value the optimizer chooses a value among the previously seen values for each parameter;
1 means "full exploration, except for categories", as with this value the optimizer for a non-categorical parameter any value among all its domain values can be chosen, while only values (categories) that have already been seen in previous configurations are chosen for a categorical parameter;
FULL_EXPLORATION
means "full exploration, including categories" as with this value the optimizer chooses any value among all its domain values, including categories, even if not already seen in previous configurations.
In case the desired explorationFactor
is 1 but there are some specific parameters that also need to be explored with respect to all its categories, then PRESET steps (refer to the Preset step page) can be used to run an optimization study with these values. For an example of a live optimization study where this approach is adopted see Optimizing a live full-stack deployment (K8s + JVM).
The following fragment refers to an optimization study that runs 100 experiments using the SOBOL optimizer and forces 50% of the experiments to use the beta-warping option, enabling a more sophisticated but longer optimization:
Online Mode | Safety Mode | Workload strategy |
---|---|---|
onlineMode
string
RECOMMEND
, FULLY_AUTONOMOUS
Changes are approved automatically or must be edited/approved by the user
safetyMode
string
LOCAL
, GLOBAL
Defines how Akamas optimizer evaluates goal constraints
safetyFactor
decimal
between 0 and 1
Parameter that impacts the distance from goal constraints for new configurations
workloadOptimizedForStrategy
string
LAST
, MOST_VIOLATED
, MAXIMIN
Selects the computation strategy to generates future configurations
explorationFactor
decimal, string
between 0 and 1 or FULL_EXPLORATION
Set the tendency to explore toward unexplored configuration values
experimentsWithBeta
decimal / string
if string must be a percentage between 0% and 100%. If numeric must be less than or equal to numberOfExperiments
Percentage/number of experiments that will be computed with beta-warping optimization
RECOMMEND
GLOBAL
MAXIMIN
FULLY_AUTONOMOUS
LOCAL
LAST