LoadRunnerEnteprise Operator
This page introduces the LoadRunnerEnterprise operator, a workflow operator that allows piloting performance tests on a target system by leveraging Micro Focus LoadRunner Enterprise (formerly known as Performance Center).
Prerequisites
This section provides the minimum requirements that you should meet to use this operator.
Supported versions
Micro Focus Performance Center 12.60 or 12.63
LoadRunner Enterprise 2020 SP3
Configuration options
When you define a task that uses the LoadRunnerEnterprise operator you should specify some configuration information to allow the operator to connect to LoadRunner Enterprise and execute a provided test scenario.
You can specify configuration information within the arguments
that are part of a task in the YAML of the definition of a workflow.
You can avoid specifying each configuration information at the task level, by including a component
property with the name of a component; in this way, the operator will take any configuration information from the properties of the referenced component
Operator arguments
This table reports the configuration reference for the arguments
section
address
String
A valid URL I.e. http://loadrunner-enterprise.yourdomain.com
Yes
-
The information required to connect to LoadRunner Enterprise.
username
String
-
Yes
-
The username used to connect to LoadRunner Enterprise
password
String
-
Yes
-
The password for the specified user
tenantID
String
-
No
-
The id of the tenant (Only for LR2020)
domain
String
-
Yes
The Domain of your load test projects.
project
String
-
Yes
The Project name of your load test projects
testId
Number
-
Yes
The id of the load test. See here below how to retrieve this from LoadRunner.
testSet
String
-
Yes
-
The name of the TestSet. See here below how to retrieve this from LoadRunner.
timeSlot
String
A number followed by the time unit.
Values must be multiple of 15m and greater then 30m
Valid units are:
m: minutes
h: hours
Yes
-
The reserved time slot for the test.
Examples:
1h
45m
1h30m
component
String
A valid component name
No
-
The name of the component from which the operator will take its configuration options
pollingInterval
Number
A positive integer number
No
30
The frequency (in seconds) of at witch Akamas checks for the load test status
verifySSL
String
True, False
No
True
Wether to validate the certificate provided by the LRE server when using an https connection
How to retrieve the testId
value
testId
valueThe following screenshot from Performance Center shows the testId
value highlighted.
How to retrieve the testSet
value
testSet
valueThe following screenshot from Performance Center shows the testSet
name highlighted.
How to retrieve the testId
value from LoadRunner Enterprise
URL: http://<LRE address>/Loadtest/
then test management from the main menu
Examples
A simple performance test
Last updated